Parker Velcon Service Bulletin on Filter Monitors

Please find attached service bulletin from Parker Velcon regarding Filter Monitors (6 Dec 2017) and updated catalog for the 2″ CDF Monitors. Here is a summary of actions that Parker Velcon will be taking :
  • Velcon P/N CDF-2XXP: Our current qualified 2-inch fuel filter monitor has been grandfathered into the El 7th edition based on the test results recorded during the 6th edition testing. We have updated our literature to reflect t his change.
  • Velcon P/N AC0 -6XX01P: We are currently working to upgrade our 6-inch out-to-in fuel filter monitor (ACO) to the 7th edition standards, and we believe this

JIG Bulletin 105 on Filter Monitors

JIG issued Bulletin No. 105 regarding Filter Monitors on 11 Dec 2017. Please note that users of Filter Monitors are required to take certain immediate actions, which includes :

  • Replacement of Filter Monitors operating at a Differential Pressure (DP) of greater than 15 psi (1.0 bar), at max achievable flow
  • Limit of the operational DP for all filter monitors to max 15 psi (1.0 bar), at maximum achievable flow. This includes resetting DP switch levels to trigger at  15psi.
  • Introduction of a new protocol for inspection and cleaning hose-end strainers, as part of commissioning of new filter monitors on fuelling

Phasing out of Monitor Elements and replacement technology.

There has been alot of concern with regards to the release of EI 1583 7th edition and EI withdrawal of the monitor specification at the end of 2020. This would imply that Monitors will be phased out within the next few years due to increasing concerns regarding SAP migration.
Velcon’s 2″ CDF monitors currently complies with the 7th edition. However, JIG will likely recommend the changeout of monitors from 22psid to 15psid. It appears that EI will phase out monitors by the end of 2020 as well.
The people that are currently affected most by this are those that are …

ECHA Microbiology Products now available!

logo

Haneflex has been appointed by ECHA Microbiology to distribute their products in S.E. Asia (less Vietnam) for all Aviation Fuel Supply customers.

ECHA Microbiology has been helping organisations to solve their microbiological contamination and corrosion problems for more than 30 years.

By helping our customers understand and avoid the consequences and costs of microbiological contamination, we increase their safety, efficiency and predictability.

ECHA Microbiology produces one of the world’s most trusted and widely-used microbiological test kits for fuels and are trusted by many of the world’s leading producers and users of fuel, and have deep expertise in the air, sea …

Fuelco Self-Bunded Tanks

Screen Shot 2017-06-02 at 5.07.29 PM

Screen Shot 2017-06-02 at 5.04.36 PM

The Fuelco Aviation Tanks are self bunded tanks suitable for the storage of aviation fuels such as Jet Fuel and Avgas*. Tanks for diesel are also available.

These are built with a stainless steel inner tank specifically designed for aviation fuels.

An integrated dispensing package, designed specifically for your application, turns this aviation fuel tank into a turnkey refuelling system.

 

PRODUCT DESCRIPTION

Standard features:

  • Self bunded double wall design
  • 304 Stainless steel inner tank or epoxy lined
  • 304 Stainless steel piping and fittings
  • Stainless steel jiggle wire
  • Aluminium floating suction
  • Sloping floor
  • Sampling cabinet
  • Overfill protection system
  • High level